4-way, Two Position, Spring Return
Single Solenoid
Grip Nut
1/2
2.71
1.44
9.46
4-way, Two Position, Spring Return
Single Solenoid
Conduit
1/2
2.71
1.44
9.46
4-way, Two Position, Spring Return
Single Solenoid
Grip Nut
3/4
2.71
1.44
9.46
4-way, Two Position, Spring Return
Single Solenoid
Conduit
3/4
2.71
1.44
9.46
4-way, Two Position, Spring Return
Single Air Pilot
Air Pilot
1/2
2.44
1.44
6.56
4-way, Two Position, Spring Return
Single Air Pilot
Air Pilot
3/4
2.44
1.44
6.56
4-way, Two Position, Detent
Double Solenoid
Grip Nut
1/2
2.71
1.44
13.3
4-way, Two Position, Detent
Double Solenoid
Conduit
1/2
2.71
1.44
13.3
4-way, Two Position, Detent
Double Solenoid
Grip Nut
3/4
2.71
1.44
13.3
4-way, Two Position, Detent
Double Solenoid
Conduit
3/4
2.71
1.44
13.3
4-way, Two Position, Detent
Double Air Pilot
Air Pilot
1/2
2.44
1.44
7.5
4-way, Two Position, Detent
Double Air Pilot
Air Pilot
3/4
2.44
1.44
7.5
4-way, Three Position, Spring Center, All Ports Blocked In Center Position
Double Solenoid
Grip Nut
1/2
2.71
1.44
13.3
4-way, Three Position, Spring Center, All Ports Blocked In Center Position
Double Solenoid
Conduit
1/2
2.71
1.44
13.3
4-way, Three Position, Spring Center, All Ports Blocked In Center Position
Double Solenoid
Grip Nut
3/4
2.71
1.44
13.3
4-way, Three Position, Spring Center, All Ports Blocked In Center Position
Double Solenoid
Conduit
3/4
2.71
1.44
13.3
4-way, Three Position, Spring Center, All Ports Blocked In Center Position
Double Air Pilot
Air Pilot
1/2
2.44
1.44
7.5
4-way, Three Position, Spring Center, All Ports Blocked In Center Position
Double Air Pilot
Air Pilot
3/4
2.44
1.44
7.5
4-way, Three Position, Spring Center, Cyl. Ports Open To Exhaust In Center Position
Double Solenoid
Grip Nut
1/2
2.71
1.44
13.3
4-way, Three Position, Spring Center, Cyl. Ports Open To Exhaust In Center Position
Double Solenoid
Conduit
1/2
2.71
1.44
13.3
4-way, Three Position, Spring Center, Cyl. Ports Open To Exhaust In Center Position
Double Solenoid
Grip Nut
3/4
2.71
1.44
13.3
4-way, Three Position, Spring Center, Cyl. Ports Open To Exhaust In Center Position
Double Solenoid
Conduit
3/4
2.71
1.44
13.3
4-way, Three Position, Spring Center, Cyl. Ports Open To Exhaust In Center Position
Double Air Pilot
Air Pilot
1/2
2.44
1.44
7.5
4-way, Three Position, Spring Center, Cyl. Ports Open To Exhaust In Center Position
Double Air Pilot
Air Pilot
3/4
2.44
1.44
7.5
* All Solenoids are 120V/60Hz, Other Voltages Available; See Voltage Selection Chart
B
Cable Grip with Indicator Light 110/120 VAC/DC
D
5-ft Molded Cable 0-220 VAC/DC
E
5-ft Molded Cable with Indicator Light and Surge Suppression, 24 VAC/DC
G
5-ft Molded Cable with Indicator Light and Surge Suppression, 110 VAC/DC
X
Solenoid Without Connector
* Substitute Letter in Position 13
OPTIONS
Voltage Selection Chart:
Substitute Letter in Position 12 | 3.5-Watt, Nominal
J: 120V/60Hz-110V/50Hz, 3.5-Watt
L: 24V/60Hz/50z, 3.5-Watt
M: 6VDC, 2-Watt
N: 12 VDC, 2-Watt
P: 24 VDC, 2-Watt
S: 110 VDC, 3.4-Watt
SPECIFICATIONS AND TECHNICAL DATA
Fluids: Filtered Lubricated or Non-Lubricated Compressed Air
Pressure Range:
Solenoid w/ Internal Pilot Supply: 20 to 150 PSIG
Solenoid w/ External Pilot Supply: 10" Hg (vacuum) to 150 PSIG
Air Pilot Operation: 10" Hg (vacuum) to 150 PSIG
Temperature Range:
Solenoid Valves: -20 to 120 Degrees Fahrenheit
Air Pilot Valves: -20 to 160 Degrees Fahrenheit
Average Flow Factor: 5.0 Cv
Minimum Pilot (Operating Pressure):
Single Solenoid: 40 PSIG
Double Solenoid, Detent: 30 PSIG
Double Solenoid, Spring Center: 40 PSIG
Voltages:
Standard: 120 VAC, 3.5 Watts
Optional:
24 VAC: 3.5 Watts
240 VAC: 7.5 Watts
12 VDC: 2.0 Watts
24 VDC: 2.0 Watts
Duty: Continuous at 90 to 105% of Rated Voltage
Coil Type: Class H. Molded w/ 3-Pin Plug-In Connector
Enclosure Classification: NEMA 4 per DIN 40050-IP65
Override: Manual, Non-Locking
MATERIALS OF CONSTRUCTION
Body: Aluminum
Spool: Anodized Aluminum
Seals: Nitrile
Solenoid Base: PPS Plastic
Operator Housing: Zinc
https://catalogs.jhf.com/Pneumatic-and-Hydraulic-Equipment/734/