OPTIONS
P72F-***-*** or P74F-***-***
Port Size
1/4" NPT: Use -2 in the 5th position.
3/8" NPT: Use -3 in the 5th position.
1/2" NPT: Use -4 in the 5th position.
3/4" NPT: Use -6 in the 5th position.
Threads
PTF Threads: A in the 6th position.
Operator Adapter Plate
Air Pilot: A in the 7th position.
Air Pilot w/ Lockout Slide: B in the 7th position.
Solenoid Pilot: C in the 7th position.
Solenoid Pilot w/ Lockout Slide: D in the 7th position.
Optional Solenoid Operator Override
Non-Locking: Use P in the 8th position.
Locking, Screwdriver Slot: Use S in the 8th position.
No Solenoid Operator: Use N in the 8th position.
Optional Solenoid Coil Voltage & Power Requirement
6 VDC, 2.00 Watts: Use D in the 9th position.
12 VDC, 2.0 Watts: Use E in the 9th position.
24 VDC, 2.0 Watts: Use F in the 9th position.
110 VDC, 3.4 Watts: Use H in the 9th position.
24 VAC, 2.5 Va: Use C in the 9th position.
220/240 VAC, 8 Va, 50/60 Hz: Use K in the 9th position.
No Solenoid Operator: Use N in the 9th position.
110/120 VAC, 2.5 Va: Use A in the 9th position.
Optional Solenoid Electrical Connector
Cable Grip Connector: Use A in the 10th position.
Cable Grip w/ Indicator Lights (Use Only w/ A and F Coils): Use B in the 10th position.
1/2" NPT Conduit: Use C in the 10th position.
No Electrical Connector: Use N in the 10th position.
SPECIFICATIONS / TECHNICAL DATA
Fluid: Filtered and Lubricated Compressed Air
Main Valve Inlet Pressure Range:
w/ Solenoid Operator: 44 to 150 PSIG
w/ Air Operator: 44 to 250 PSIG
Operating Temperature Range:
w/ Solenoid Operator: 0 to +120 Degrees Fahrenheit
w/ Air Operator: 0 to +150 Degrees Fahrenheit
Maximum Flow: 45 SCFM
Average Flow Factor (Cv):
In-Out Ports: 1.6
Out-Exhaust Ports: 1.7
Snap Pressure: Full flow when downstream pressure reaches 50 to 80% inlet pressure.